Skip to content

Publications Z320-11 (R2016)

Z320-11 (R2016)

Z320-11 (R2016) – Building Commissioning Standard & Check Sheets

Publication Year:

  • 2011

Total Pages:

94

Reaffirmed Year:

  • 2016

Publisher:

  • CSA

What Others Bought

  • Sorry, no image available for CAN/CSA-Z8001-13

    Publications

    CAN/CSA-Z8001-13

    CAN/CSA-Z8001-13 - Commissioning of health care facilities

  • Sorry, no image available for CAN/CSA-F378 SERIES-11

    Publications

    CAN/CSA-F378 SERIES-11

    CAN/CSA-F378 SERIES-11 - Solar collectors

  • Sorry, no image available for Z275.3-09 (R2014)

    Publications

    Z275.3-09 (R2014)

    Z275.3-09 (R2014) - Occupational safety code for work in compressed air environments

  • Sorry, no image available for M421-11 (R2016)

    Publications

    M421-11 (R2016)

    M421-11 (R2016) - Use of electricity in mines

  • Sorry, no image available for B64.10-11/B64.10.1-11 (R2016)

    Publications

    B64.10-11/B64.10.1-11 (R2016)

    B64.10-11/B64.10.1-11 (R2016) - Selection and installation of backflow preventers/Maintenance and field testing of backflow preventers

  • Sorry, no image available for CAN/CSA-B64 SERIES-11 (R2016)

    Publications

    CAN/CSA-B64 SERIES-11 (R2016)

    CAN/CSA-B64 SERIES-11 (R2016) - Backflow preventers and vacuum breakers (Consists of B64.0, B64.1.1, B64.1.2, B64.1.3, B64.1.4, B64.2, B64.2.1, B64.2.1.1, B64.2.2, B64.3, B64.3.1, B64.4, B64.4.1, B64.5, B64.5.1, B64.6, B64.6.1, B64.7, B64.8 and B64.9)

  • Sorry, no image available for Archive

    Publications

    Archive

    CSA Archive Product

  • Sorry, no image available for S250-11

    Publications

    S250-11

    S250-11 - Mapping of underground utility infrastructure

click to view next item

CSA In The News

"Canadian Standards Association Z320 commissioning standard brings needed 'holistic' approach"
- Daily Commerical News & Construction Record. Read more.

Overview

Until recently, owners of newly constructed and renovated buildings had no way of knowing if the technical functions associated with their major systems were safe and fully operational. To help the interest of safety and quality assurance, CSA Group published this standard to help address important issues of quality assurance and safety.

Z320 provides guidelines for commissioning of buildings and all related systems, and has been developed to deal with buildings and their major systems as a whole, rather than as individual stand-alone components. It can be applied to new construction as well as renovations of existing buildings or facilities.

This is the first edition of CSA Z320, Building commissioning. This Standard provides guidelines for the commissioning of buildings and all related building systems, and has been developed to deal with buildings and/or their major systems as a whole, rather than as separate individual stand-alone components. It applies to new construction and to renovations of existing buildings or facilities.

The intent of this Standard is to provide a comprehensive, integrated, consistent, and managed process to ensure and document the performance of a complete building and its major systems in meeting the basis of design and operational requirements of the owner.

Major building systems included are:

  • architectural systems (building envelope and interior space assemblies that are environmental separators);

  • vertical and horizontal transportation systems;

  • electrical systems (incoming, main, and branch distribution; fire alarm and detection systems);

  • mechanical systems (HVAC, plumbing, fire protection, and refrigeration); and

  • control systems and integration (BAS, energy management control systems, lighting control systems).
This Standard has been developed to assist the commissioning team in the preparation and implementation of a commissioning plan. A commissioning plan specifies commissioning requirements for newly installed or renovated building systems and includes, but is not limited to, descriptions of the following:

  • the commissioning process;

  • the resources required to complete commissioning;

  • the responsibilities of the commissioning team; and

  • the sequence and integration of commissioning activities.
The intended users of the standard may include workers and professionals who perform technical functions associated with any of these phases of operation as well as stakeholders who have an interest in building safety or related quality assurance, (i.e. developers, general contractors, property marketers, regulators, commissioning providers and consumers). The standard may also facilitate certification to green building rating systems.

The Technical Committee has developed non mandatory annexes (written in mandatory language) to provide further explanatory information. Included in these annexes are sections on recommissioning and retro-commissioning.

Note: Mandatory language will allow an individual/organization to reference an annex as a project specification.

Publication type

Print Page

Tell a Friend

GST REG No R119441681
QST REG No R1006017360