Skip to content

Publications C22.1-09 PACKAGE

Sorry, no image available for C22.1-09 PACKAGE

C22.1-09 PACKAGE - Consists of C22.1-09, Canadian electrical code, part I (21st edition), safety standard for electrical installations; CE code pocket reference book and the C22.1HB-09, CE code handbook, an explanation of rules of the canadian electrical code, part I

Publication Year:

  • 2009

Total Pages:

1304

Publisher:

  • CSA

What Others Bought

  • Sorry, no image available for C22.2 NO. 73-1953 (R2009)

    Publications

    C22.2 NO. 73-1953 (R2009)

    C22.2 NO. 73-1953 (R2009) - Construction and Test of Electrically Equipped Machine Tools

  • Sorry, no image available for CAN/CSA-C22.3 NO. 7-10

    Publications

    CAN/CSA-C22.3 NO. 7-10

    CAN/CSA-C22.3 NO. 7-10 - Underground systems

  • Sorry, no image available for CAN/CSA-C22.2 NO. 0-10

    Publications

    CAN/CSA-C22.2 NO. 0-10

    CAN/CSA-C22.2 NO. 0-10 - General requirements - Canadian electrical code, part II

  • C22.1-09

    Publications

    C22.1-09

    C22.1-09 - Canadian electrical code, part I (21st edition), safety standard for electrical installations

  • Sorry, no image available for CAN/CSA-Z434-03 (R2013)

    Publications

    CAN/CSA-Z434-03 (R2013)

    CAN/CSA-Z434-03 (R2013) - Industrial Robots and Robot Systems - General Safety Requirements

  • Sorry, no image available for C22.10-10 PACKAGE

    Publications

    C22.10-10 PACKAGE

    C22.10-10 PACKAGE - Consists of C22.10-10, Québec Construction Code, Chapter V - Electricity Canadian Electrical Code, Part I (Twenty-first edition) with Québec Amendments and the C22.1HB-09, CE Code Handbook, An Explanation of Rules of the Canadian Electrical Code, Part I.

  • Sorry, no image available for CAN/CSA-C22.2 NO. 0.4-04 (R2009)

    Publications

    CAN/CSA-C22.2 NO. 0.4-04 (R2009)

    CAN/CSA-C22.2 NO. 0.4-04 (R2009) - Bonding of Electrical Equipment

  • Sorry, no image available for CAN/CSA-Z460-05 (R2010)

    Publications

    CAN/CSA-Z460-05 (R2010)

    CAN/CSA-Z460-05 (R2010) - Control of Hazardous Energy - Lockout and Other Methods

  • Sorry, no image available for CAN/CSA-C22.2 NO. 257-06 (R2011)

    Publications

    CAN/CSA-C22.2 NO. 257-06 (R2011)

    CAN/CSA-C22.2 NO. 257-06 (R2011) - Interconnecting Inverter-Based Micro-Distributed Resources to Distribution Systems

  • Sorry, no image available for CAN/CSA-Z662-11 PACKAGE

    Publications

    CAN/CSA-Z662-11 PACKAGE

    CAN/CSA-Z662-11 PACKAGE - Consists of CAN/CSA-Z662-11, Oil and gas pipeline systems and Z662.1-11, Commentary on CAN/CSA-Z662-11, Oil and gas pipeline systems

  • Sorry, no image available for CE CODE SAFETY PACKAGE

    Publications

    CE CODE SAFETY PACKAGE

    CE CODE SAFETY PACKAGE - Consists of C22.1-12, Canadian electrical code, part I (22nd edition), safety standard for electrical installations; CE code pocket reference book; C22.1HB-12, CE code handbook, an explanation of rules of the Canadian electrical code, part I and Z462-12, Workplace electrical safety.

click to view next item
C22.1-09 - Canadian electrical code, part I (21st edition), safety standard for electrical installations

Intended Use

The Canadian Electrical Code, Part I is adopted across Canada as regulation for the installation and maintenance of electrical equipment. It is integrated with CSA electrical equipment standards (collectively known as the Canadian Electrical Code, Part II) to ensure that electrical products evaluated in accordance with the applicable Part II standard are suitable for installation in accordance with the Rules of Part I.

The Canadian Electrical Code, Part I covers all electrical work and electrical equipment operating or intended to operate at all voltages in electrical installations for buildings, structures, and premises, including factory-built relocatable and non-relocatable structures, and self-propelled marine vessels stationary for periods exceeding five months and connected to a shore supply of electricity continuously or from time to time.

Preface

This twenty-first edition of the Canadian Electrical Code, Part I, was approved by the Committee on the Canadian Electrical Code, Part I, and by the Regulatory Authority Committee at their June 2008 meetings in Calgary, Alberta. This twenty-first edition supersedes the previous editions, published in 2006, 2002, 1998, 1994, 1990, 1986, 1982, 1978, 1975, 1972, 1969, 1966, 1962, 1958, 1953, 1947, 1939, 1935, 1930, and 1927.

A new Section 58 was added to cover requirements for passenger ropeways and similar equipment. In addition, there are significant changes to Sections 0, 10, 18, 26, 46, and 68. Sections 12 and 32 have been revised to reflect new technology and industry practices.

The designation for receptacle configuration type 5-20RA ("T-slot") has been revised to 5-20R throughout the Code, and the configuration previously designated as 5-20R is now designated 5-20RA to recognize that this configuration is being phased out. Similarly, the designations for 6-20R and 6-20RA configurations have been interchanged throughout the Code.

The term "light fixture" has been replaced by "luminaire" throughout the Code, and all references to HFT conduit have been deleted.

Scope

This Code covers all electrical work and electrical equipment operating or intended to operate at all voltages in electrical installations for buildings, structures, and premises, including factory-built relocatable and non-relocatable structures, and self-propelled marine vessels stationary for periods exceeding five months and connected to a shore supply of electricity continuously or from time to time, with the following exceptions: a) installations or equipment employed by an electric, communication, or community antenna distribution system utility in the exercise of its function as a utility, as recognized by the regulatory authority having jurisdiction, and located outdoors or in buildings or sections of buildings used for that purpose; b) equipment and facilities that are used in the operation of an electric railway and are supplied exclusively from circuits that supply the motive power; c) installations or equipment used for railway signalling and railway communication purposes, and located outdoors or in buildings or sections of buildings used exclusively for such installations; d) aircraft; and e) electrical systems in ships that are regulated under Transport Canada. For mines and quarry applications, see also CAN/CSA-M421.

This Code and any standards referenced in it do not make or imply any assurance or guarantee by the authority adopting this Code with respect to life expectancy, durability, or operating performance of equipment and materials so referenced.

-----------------------------------------------------------------------

C22.1HB-09 - CE code handbook, an explanation of rules of the Canadian electrical code, part 1

This Handbook provides background information on the reasons behind the requirements in the Canadian Electrical Code, Part I, and gives an explanation of each Rule in plain, easy-to-understand language. The Handbook is intended to provide a clearer understanding of the safety requirements of the Code.

The content of this Handbook is not meant to form a code of mandatory requirements. The mandatory language ("shall") that is used in the CE Code, Part I, has not been used here. Care has been taken to ensure that the intent of the Code Rules is clear to the users of the Handbook. However, users of the Handbook must not under any circumstances rely on it to determine the current requirements of the Code. As always, reference must be made to the Code itself and any local amendments. CSA does not assume responsibility for any errors or omissions resulting from the information contained in this Handbook.

The Rules in the CE Code, Part I, are divided into two groups. Sections 0 to 16 and 26 are considered General Sections, and the other Sections supplement or amend those General Sections. Therefore a requirement in the supplementary Sections takes precedence over a general requirement. For example,

Rule 12-1008 requires three threads to be engaged when making a threaded connection, whereas Rule 18-106 requires five threads to be engaged when making a threaded connection in a Class I, Zone 1 area.

Section 4 permits the use of aluminum conductors, but Rule 32-100 does not allow aluminum conductors to be used in fire alarm systems.

Publication type

GST REG No R119441681
QST REG No R1006017360