Z1006-10
Z1006-10 - Management of work in confined spaces
What Others Bought
-
Z259.11-05 (R2010) - Energy Absorbers and Lanyards
-
Z195.1-02 - Guideline on Selection, Care, and Use of Protective Footwear
-
CAN/CSA-Z94.4-11 - Selection, use, and care of respirators
-
C22.10-10 - Québec Construction Code, Chapter V - Electricity Canadian Electrical Code, Part I (Twenty-first edition) with Québec Amendments
-
Z432-04 (R2009) - Safeguarding of Machinery
-
CAN/CSA-Z460-05 (R2010) - Control of Hazardous Energy - Lockout and Other Methods
-
Z462-12 - Workplace electrical safety
-
Z797-09 - Code of practice for access scaffold
-
ASME-BPVC-SEC 7-2010 - Section 7 - Recommended guidelines for the care of power boilers
-
C22.1-12 PACKAGE - Consists of C22.1-12, Canadian electrical code, part I (22nd edition), safety standard for electrical installations; CE code pocket reference book and the C22.1HB-12, CE code handbook, an explanation of rules of the canadian electrical code, part I
Preface
This is the first edition of CSA Z1006, Management of work in confined spaces.
Scope
1.1 This Standard specifies requirements for (a) establishing and maintaining a confined space management program in accordance with OHSMS principles; (b) the roles and responsibilities of the management representative, entry team, and emergency response team; (c) management of external service providers; (d) identification and designation of confined spaces; (e) design and engineering of confined spaces; (f) hazard identification and risk assessment relating to work in confined spaces; (g) management and control of hazards and risks associated with work in confined spaces; (h) general safety procedures for confined spaces; (i) personal protective equipment (PPE) and other equipment used for work in confined spaces; (j) emergency plans for rescuing workers in confined spaces; (k) training for work in confined spaces; and (l) determining fitness for work in confined spaces.
1.2 This Standard does not address safety management of (a) enclosures or structures designed and constructed for continuous human occupancy; or (b) underwater enclosures. Note: For underwater enclosures see the requirements for penetration diving specified in CAN/CSA-Z275.2.
1.3 This Standard is designed to be used with related occupational or technical standards. It is intended to be referenced by other Standards as the primary set of requirements for health and safety management of work in confined spaces.
1.4 This Standard is designed for voluntary application in Canadian workplaces. However, the principles established in this Standard are based on best practices recognized internationally. As such they may be applied to any workplace.
1.5 At the time of publication, confined space legislation differs from jurisdiction to jurisdiction in Canada. It is the user's responsibility to determine how applicable legislative requirements relate to this Standard.
1.6 In CSA Standards, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; "may" is used to express an option or that which is permissible within the limits of the standard; and "can" is used to express possibility or capability. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
1.7 The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only.